* Home > Product Info > Test & Measurement > DC Power Supply > Remote Control Type > PAS3030R  
  FEATURES

- constant voltage and current operation
- excellent load, line & Ripple Specifications
- each output has a readout for voltage and current (3 digit red LED display)
- coarse and fine voltage controls for accurate voltage and current settings
- indicators for constant voltage, constant current and overload operation
- Simultaneous display
- Floating output terminals
- Series / parallel operation
- Remote sensing terminal

MODEL
PAS3030R
Output
Voltage
0 to 30V
Current
0 to 3A
Constant
Voltage
Load Regulation
(0 to 100% load variation)
5mV
Line Regulation
(0 to 10% line variation)
5mV
Ripple & Noise (rms)
0.5mV
Constant
Current
Load Regulation
(0 to 100% load variation)
10mA
Line Regulation
(0 to 10% line variation)
2mA
Ripple & Noise (rms)
3mA
Display
Voltmeter
Type
3 digit red LED
Accuracy
¡¾(0.2% Rdg + 2 digits)
Resolution
100mV
Ammeter
Type
3 digit red LED
Accuracy
¡¾(1.0% Rdg + 3 digits)
Resolution
10mA
LED indicators
Green LED :CV, Red LED : CC
Ground Proof Voltage
¡¾ 200V
Remote Programming
External programming Voltage terminals
Varies the output linearly from 0 to maximum output Voltage.
¡¾5% (or current in the constant current mode) when 0 to 10V is applied.
External programming Resistance terminals
Varies the output linearly from 0 to maximum output Voltage.
¡¾5% (or current in the constant current mode) when 0 to 10§Ú is applied.
Remote sensing
R type only
Remote ON/OFF
R type only (Front panel remote on/off swtitch)
Master slave
One master controls or more slave units in series or parallel
Note : Parallel units must be the same model
Insulation Resistance
30§Û @ DC 500V : AC Input to Chassis
20§Û @ DC 500V : Output Terminal to Chassis
Temperature
Operating Temperature
0¡É to 40¡É, 10 to 80% RH
Storage Temperature
-20¡É to 60¡É, 10 to 85% RH
Cooling Method
Free Air
Power
Input Power
110V/120V/220V/230V Selectable
Dimensions
Size ( W ¡¿ H ¡¿ D )
138 ¡¿ 162 ¡¿ 345 mm
Weight
6.6Kg
Accessories
Instruction Manual, Power Cable, Test Leads, Spare Fuse