Display
|
3.75 digit, LCD width 2 times/second
sampling
|
Bar Graph Display
|
32 Segments with 12 times/second
sampling
|
Ranging
|
Auto-ranging
|
Polarity
|
Automatic, minus(-) sign indicates
for negative polarity
|
Data Hold
|
Freezes displayed reading
|
Auto Power Off
|
Meter automatically shuts off 10
minutes after last operation
|
Power Source
|
2 x LR-44 or 357 Cells
|
Power Consumption
|
5mW(Typical)
|
Dimensions
|
54(W) x 108(H) x 12(D) mm
|
Weight
|
Approx. 400g (including batteries and
case)
|
Range and Accuracy
|
DC Voltage
|
300mV
|
¡¾ 1.3% of reading and ¡¾2 digits
|
3V
|
¡¾ 0.7% of reading and ¡¾2 digits
|
3-30-300-450V
|
¡¾ 1.3% of reading and ¡¾2 digits
|
AC Voltage
|
3-30-300-450V |
¡¾ 2.3% of reading and ¡¾5
digits
|
Resistance
|
300 ohms
|
¡¾ 2.0% of reading and ¡¾4 digits
|
3-30-300K ohms
|
¡¾ 2.0% of reading and ¡¾2 digits
|
3M ohms
|
¡¾ 6.0% of reading and ¡¾2 digits
|
30M ohms
|
¡¾ 10% of reading and ¡¾5 digits
|
Input Impedance
|
10M¥Ø (DCV/ACV) more than 100M¥Ø on
300mV DC
|